Iimveliso

  • Factory unikezelo ngqo isivamvo pH for Sewage Chemical ishishini CS1540

    Factory unikezelo ngqo isivamvo pH for Sewage Chemical ishishini CS1540

    CS1540 inzwa ye-pH
    Yenzelwe umgangatho wamanzi wento ethile.
    I-1.CS1540 i-pH electrode ithatha eyona dielectric eqinileyo ehamba phambili kwihlabathi kunye nendawo enkulu ye-PTFE ye-junction yolwelo. Akukho lula ukubhloka, kulula ukuyigcina.
    2.Indlela yokusabalalisa ireferensi yobude obude kwandisa kakhulu ubomi benkonzo ye-electrode kwiindawo ezinzima. Iglowubhu yeglasi esanda kuyilwa yongeza indawo yebhalbhu, ithintela ukuveliswa kwe
    amaqamza aphazamisayo kwi-buffer yangaphakathi, kwaye yenza umlinganiselo uthembeke ngakumbi.
    3.Adopt igobolondo le-Titanium alloy, phezulu kunye nezantsi i-PG13.5 intambo yombhobho, kulula ukuyifaka, akukho mfuneko ye-sheath, kunye neendleko eziphantsi zokufakela. I-electrode ihlanganiswe ne-pH, ireferensi, isisombululo somhlaba.
    I-4.I-electrode ithatha i-high-quality-low-noise cable, enokuyenza imveliso yesignali ibe ngaphezu kweemitha ezingama-20 ngaphandle kokuphazamiseka.
    I-5.I-electrode yenziwe ngefilimu yeglasi ye-ultra-bottom impedance-sensitive, kwaye nayo ineempawu zokuphendula ngokukhawuleza, ukulinganisa ngokuchanekileyo, ukuzinza okulungileyo, kwaye akulula ukwenza i-hydrolyze kwimeko ye-conductivity ephantsi kunye namanzi aphezulu ahlambulukileyo.
  • Ephathekayo Residual Chlorine Meter Uvavanyo lomgangatho weOzone ipeni yovavanyo

    Ephathekayo Residual Chlorine Meter Uvavanyo lomgangatho weOzone ipeni yovavanyo

    Ukusetyenziswa kwendlela ye-electrode emithathu kukuvumela ukuba ufumane iziphumo zokulinganisa ngokukhawuleza nangokuchanekileyo ngaphandle kokutya nayiphi na i-reagents ye-colorimetric. I-FCL30 epokothweni yakho liqabane elikrelekrele lokulinganisa i-ozone enyibilikileyo nawe.
  • Amanzi i-Ph Meter yeDijithali yoMlunga waManzi woMvavanyi wePH kumadama

    Amanzi i-Ph Meter yeDijithali yoMlunga waManzi woMvavanyi wePH kumadama

    Imveliso eyenzelwe ngokukodwa ukuvavanya ixabiso le-pH onokuthi uvavanye ngokulula kwaye ulandele ixabiso le-asidi yesiseko sento evavanyiweyo. I-pH30 yeemitha ikwabizwa ngokuba yi-acidometer, sisixhobo esilinganisa ixabiso le-pH kulwelo, ebisetyenziswe ngokubanzi kuvavanyo lomgangatho wamanzi. Imitha ye-pH ephathekayo inokuvavanya isiseko se-asidi emanzini, esetyenziswa kwiindawo ezininzi ezifana ne-aquaculture, unyango lwamanzi, ukubeka iliso kokusingqongileyo, ukulawulwa komlambo njalo njalo. Ichanekile kwaye izinzile, inoqoqosho kwaye iluncedo, kulula ukuyigcina, i-pH30 izisa lula ngakumbi, yenza amava amatsha e-acid-base application.
  • pH Meter/pH Umvavanyi-pH30

    pH Meter/pH Umvavanyi-pH30

    Imveliso eyenzelwe ngokukodwa ukuvavanya ixabiso le-pH onokuthi uvavanye ngokulula kwaye ulandele ixabiso le-asidi yesiseko sento evavanyiweyo. I-pH30 yeemitha ikwabizwa ngokuba yi-acidometer, sisixhobo esilinganisa ixabiso le-pH kulwelo, ebisetyenziswe ngokubanzi kuvavanyo lomgangatho wamanzi. Imitha ye-pH ephathekayo inokuvavanya isiseko se-asidi emanzini, esetyenziswa kwiindawo ezininzi ezifana ne-aquaculture, unyango lwamanzi, ukubeka iliso kokusingqongileyo, ukulawulwa komlambo njalo njalo. Ichanekile kwaye izinzile, inoqoqosho kwaye iluncedo, kulula ukuyigcina, i-pH30 izisa lula ngakumbi, yenza amava amatsha e-acid-base application.
  • Nitrate Ion Selective Electrod RS485 Output Isivamvo somgangatho wamanzi ca2+ ion Electrode for waste Water CS6720AD

    Nitrate Ion Selective Electrod RS485 Output Isivamvo somgangatho wamanzi ca2+ ion Electrode for waste Water CS6720AD

    I-CS6720AD yedijithali ye-nitrate ion electrode ekhethiweyo luhlobo lwenzwa ye-electrochemical esebenzisa i-membrane enokubakho ukulinganisa umsebenzi okanye ukuxinwa kwee-ion kwisisombululo. Xa idibana nesisombululo esine-ion ekufuneka ilinganiswe, iya kuvelisa unxibelelwano kunye ne-sensor kwi-interface phakathi kwe-membrane yayo ebucayi kunye nesisombululo. Umsebenzi we-ion uhambelana ngokuthe ngqo kwi-membrane enokwenzeka. Ii-electrode ezikhethiweyo ze-ion zikwabizwa ngokuba yi-membrane electrode. Olu hlobo lwe-electrode lune-membrane ye-electrode ekhethekileyo ephendula ngokufanelekileyo kwii-ion ezithile. Ubudlelwane phakathi kwesakhono senwebu ye-electrode kunye nomxholo we-ion oza kulinganiswa uhambelana nefomula yeNernst. Olu hlobo lwe-electrode luneempawu zokukhetha okulungileyo kunye nexesha elifutshane lokulinganisa, okwenza kube yinto esetyenziswa ngokuqhelekileyo isalathisi se-electrode ukuhlalutya okunokwenzeka.
  • Umzi-mveliso waManzi wokuqina kwemitha NH4 Ion eKhethekileyo ye-Electrode Sensor Probe RS485 CS6718AD

    Umzi-mveliso waManzi wokuqina kwemitha NH4 Ion eKhethekileyo ye-Electrode Sensor Probe RS485 CS6718AD

    Kulula ukuxhuma kwi-PLC, i-DCS, iikhomputha zokulawula i-industrial, abalawuli benjongo ngokubanzi, izixhobo zokurekhoda ezingenamaphepha okanye izikrini zokuthintela kunye nezinye izixhobo ze-third party.I-CS6718AD yamanzi obunzima be-ion electrode ekhethiweyo yindlela esebenzayo yokulinganisa umxholo we-calcium ion kwisampuli. Iielectrode ezikhethiweyo ze-calcium ion zikwasetyenziswa rhoqo kwizixhobo ze-intanethi, ezifana ne-industrial online ion ion
    esweni umxholo. I-electrode ekhethiweyo ye-calcium ion ineenzuzo zokulinganisa okulula, ukuphendula ngokukhawuleza kunye nokuchanekileyo. Ingasetyenziswa nge-PH imitha, imitha ye-ion kunye ne-online calcium ion analyzer, kwaye ikwasetyenziswa kwi-electrolyte analyzer, kunye ne-ion selective electrode detector ye-flow injection analyzer.
  • Kwi-Intanethi i-Ammonia Ammonium Ion-ekhethiweyo ye-Electrodes yoHlolo loMgangatho waManzi RS485 4-20mA CS6714AD

    Kwi-Intanethi i-Ammonia Ammonium Ion-ekhethiweyo ye-Electrodes yoHlolo loMgangatho waManzi RS485 4-20mA CS6714AD

    Kulula ukuxhuma kwi-PLC, i-DCS, iikhomputha zokulawula i-industrial, abalawuli benjongo ngokubanzi, izixhobo zokurekhoda ezingenamaphepha okanye izikrini zokuthintela kunye nezinye izixhobo ze-third party.I-CS6714AD i-ammonium ion ekhethiweyo ye-electrode yindlela esebenzayo yokulinganisa umxholo we-ion ammonium kwisampuli. Ii-electrode ezikhethiweyo ze-Ammonium ion zikwasetyenziswa rhoqo kwizixhobo ze-intanethi, ezinje ngemizi-mveliso ekwi-intanethi ye-ammonium ion esweni umxholo. I-Ammonium ion ekhethiweyo ye-electrode ineenzuzo zokulinganisa okulula, ukuphendula ngokukhawuleza kunye nokuchanekileyo. Ingasetyenziswa nge-PH imitha, imitha ye-ion kunye ne-online ammonium ion analyzer, kwaye isetyenziswe kuhlalutyi lwe-electrolyte, kunye ne-ion ekhethiweyo ye-electrode detector ye-flow nalizer yokuhlaziya.
  • Ukuthengiswa kweFactory kwi-Intanethi ye-Amoniya yePotassium ion Analyzer Imitha 3/4NPT yamanzi amdaka CS6712AD

    Ukuthengiswa kweFactory kwi-Intanethi ye-Amoniya yePotassium ion Analyzer Imitha 3/4NPT yamanzi amdaka CS6712AD

    Kulula ukuxhuma kwi-PLC, i-DCS, iikhomputha zokulawula i-industrial, abalawuli benjongo jikelele, izixhobo zokurekhoda ezingenamaphepha okanye izikrini zokuthintela kunye nezinye izixhobo ze-third party.I-electrode ye-potassium ye-potassium ye-CS6712AD yindlela esebenzayo yokulinganisa umxholo we-ion ye-potassium kwisampuli. Ii-electrode ezikhethiweyo ze-potassium ion zikwasetyenziswa rhoqo kwizixhobo ze-intanethi, ezinje ngokujongwa komxholo we-ion potassium kwi-intanethi. , I-Potassium ion electrode ekhethiweyo ineenzuzo zokulinganisa okulula, impendulo ekhawulezayo kunye nechanekileyo. Inokusetyenziswa ngemitha ye-PH, imitha ye-ion kunye ne-online potassium analyzer, kwaye isetyenziswe kuhlalutyi lwe-electrolyte, kunye ne-ion ekhethiweyo ye-electrode detector ye-injection analyzer.
  • Amanzi akwi-Intanethi yeDijithali RS485 iChloride Ion eKhethekileyo yoVavanyo lokuJonga amanzi CS6711AD

    Amanzi akwi-Intanethi yeDijithali RS485 iChloride Ion eKhethekileyo yoVavanyo lokuJonga amanzi CS6711AD

    I-CS6711AD i-ion sensor ye-ion ye-chloride yedijithali isebenzisa i-ion eyomeleleyo ye-membrane ekhethiweyo ye-electrode yokuvavanya i-ion ye-fluoride edada emanzini, ekhawulezayo, elula, echanekileyo kunye nezoqoqosho. Uyilo lwebhulorho yetyuwa ephindwe kabini, ubomi benkonzo ende.Iprobe ye-ion ye-chloride enelungelo elilodwa lomenzi, kunye nolwelo lwesalathiso lwangaphakathi kuxinzelelo lwe-100KPa ubuncinane (1Bar), ingena ngokucothayo ukusuka kwibhulorho yetyuwa encinci. Inkqubo enjalo yereferensi izinzile kwaye ubomi be-electrode bude kunobuqhelekileyo.
  • I-Digital Fluoride Ion ekwi-Intanethi ye-ISE Probe yeSensor yokucoca ngamanzi amdaka CS6710AD

    I-Digital Fluoride Ion ekwi-Intanethi ye-ISE Probe yeSensor yokucoca ngamanzi amdaka CS6710AD

    I-CS6710AD i-ion yedijithali ye-fluoride ion isebenzisa i-ion eyomeleleyo ye-membrane ekhethiweyo ye-electrode yokuvavanya ii-ion ze-fluoride ezidada emanzini, ezikhawulezayo, ezilula, ezichanekileyo kunye nezongayo. Uyilo lwamkela umgaqo we-electrode ye-ion eqinileyo ye-single-chip, ngokuchaneka komlinganiselo ophezulu. Uyilo lwebhulorho yetyuwa ephindwe kabini, ubomi benkonzo ende.Iprobe ye-ion ye-fluoride enelungelo elilodwa lomenzi wechiza, kunye nolwelo lwesalathiso lwangaphakathi kuxinzelelo oluyi-100KPa ubuncinane (1Bar), ingena ngokucothayo ukusuka kwibhulorho yetyuwa encinci. Inkqubo enjalo yereferensi izinzile kwaye ubomi be-electrode bude kunobuqhelekileyo.
  • T9002 Iyonke iPhosphorus kwi-Intanethi eZizimelayo zokuJonga umzi-mveliso kwi-Intanethi kwiXabiso loMzi-mveliso waManzi amdaka.

    T9002 Iyonke iPhosphorus kwi-Intanethi eZizimelayo zokuJonga umzi-mveliso kwi-Intanethi kwiXabiso loMzi-mveliso waManzi amdaka.

    1. Isishwankathelo seMveliso:
    Uninzi lwezilwanyana zaselwandle zinochuku kakhulu kwi-organophosphorus zinambuzane. Ezinye izinambuzane ezichasayo kwi-pesticide concentration zinokubulala ngokukhawuleza izinto eziphilayo zaselwandle.Kukho i-nerve ebalulekileyo eqhuba into emzimbeni womntu, ebizwa ngokuba yi-acetylcholinesterase. I-Organophosphorus inokuthintela i-cholinesterase kwaye yenze ukuba ingakwazi ukubola i-acetyl cholinesterasee, okukhokelela ekuqokeleleni okukhulu kwe-acetylcholinesterase kwiziko le-nerve, elinokukhokelela kwityhefu kunye nokufa. Ixesha elide i-organophosphorus pesticides ayinakubangela kuphela ityhefu engapheliyo, kodwa ibangele ingozi ye-carcinogenic kunye ne-teratogenic.
    I-analyzer inokusebenza ngokuzenzekelayo kwaye ngokuqhubekayo ixesha elide ngaphandle kokuya ngokwezicwangciso zesayithi. Isetyenziswa ngokubanzi kumthombo wongcoliseko lokukhupha amanzi amdaka, inkqubo yamanzi amdaka enkqubo yoshishino, amanzi amdaka eplanti yokucoca ugutyulo lwamanzi amdaka, kwindawo kamasipala yokucoca amanzi amdaka kunye nezinye izihlandlo. Ngokobunzima beemeko zovavanyo lwendawo, inkqubo yonyango lwangaphambili ehambelanayo inokukhethwa ukuqinisekisa ukuba inkqubo yovavanyo inokuthenjwa, iziphumo zovavanyo zichanekile, kwaye zihlangabezana ngokupheleleyo neemfuno zezihlandlo ezahlukeneyo.
  • T9001 Ammonia Nitrogen On-line Automatic Monitoring

    T9001 Ammonia Nitrogen On-line Automatic Monitoring

    1. Isishwankathelo seMveliso:
    I-ammonia nitrogen emanzini ibhekisa kwi-ammonia ngohlobo lweammonia yasimahla, ephuma ikakhulu kwiimveliso ezibolileyo zenitrogen-equlathe izinto eziphilayo kugutyulo lwasekhaya ziintsholongwane, amanzi amdaka emizi-mveliso afana ne-coking synthetic ammonia, kunye ne-drainage yasefama. Xa umxholo we-ammonia nitrogen emanzini uphezulu, unetyhefu kwiintlanzi kwaye unobungozi ebantwini ngamaqondo ahlukeneyo. Ukuzimisela komxholo we-ammonia nitrogen emanzini kunceda ukuvavanya ukungcola kunye nokuzicoca kwamanzi, ngoko ke i-ammonia nitrogen iyisalathisi esibalulekileyo sokungcoliseka kwamanzi.
    I-analyzer inokusebenza ngokuzenzekelayo kwaye ngokuqhubekayo ixesha elide ngaphandle kokuya ngokwezicwangciso zesayithi. Isetyenziswa ngokubanzi kumthombo wongcoliseko lwamanzi akhupha amanzi amdaka, kwindawo kamasipala yokucocwa kwamanzi amdaka, umgangatho wamanzi angaphezulu kokusingqongileyo kunye nezinye izihlandlo. Ngokobunzima beemeko zovavanyo lwendawo, inkqubo yonyango lwangaphambili ehambelanayo inokukhethwa ukuqinisekisa ukuba inkqubo yovavanyo inokuthenjwa, iziphumo zovavanyo zichanekile, kwaye zihlangabezana ngokupheleleyo neemfuno zezihlandlo ezahlukeneyo.
    Le ndlela ifanelekile kumanzi amdaka kunye ne-ammonia nitrogen kuluhlu lwe-0-300 mg/L. Ukugqithisa kwe-calcium kunye ne-magnesium ion, i-chlorine eseleyo okanye i-turbidity inokuphazamisa umlinganiselo.